RV Emerald PlusTM 6500 GenSet. See Installation Manual for details. genset, Onan offers a complete line of replacement and tune-up parts. I just got a onan gen. It's a onan emerald 1 Genset Serial # 1890266962 Model # 4BGEFA26100F RPM 800 volts 120 PH.1 It starts and runs but seems like it might need a. ONAN GENERATOR: Please note that the manual is separated into several PDF files. Some are large files and may take longer to download. Onan Emerald Plus Operators manual Ratings: (0)|Views: 22,573|Likes: 91 Onan Emerald Plus Operators Manual Onan Emerald Plus Operators Manual','url':'https://www.scribd.com/doc/22322520/Onan-Emerald-Plus-Operators-manual','og_descr':'Onan Emerald Plus Operators Manual Cummins Onan RV Generator Parts & Manuals. When reliability counts, insist on the real thing. From filters to tune-up kits, Genuine Cummins Onan Green Label Parts are. Onan Emerald 1 Manual ONAN 6500 watt Emerald III 120 240 Volt generator, low hrs 4 sale 6.5NHE-1R genset. I now am in need of a Service Manual for my. Document/File: onan-emerald-3-genset-owners-manual.pdf, filesize: n/a. Filetype: pdf.Commercial Emerald 4500 GenSet. 4.0BGD-FT/1 Gasoline 50 4000 220/380 10. emerald plus onan 4000 manual - Full Download 7,602 downloads / 4,581 KB/s. Onan Emerald Plus Operators manual - Free download as PDF File (.pdf), Text file (.txt) or read online for free. Onan Emerald Plus Operators Manual.
0 Comments
NC DHHS » Providers » Provider Info » Mental Health. Mental Health. Alcohol Drug Education Training School. CDW Online (Consumer Data Warehouse) Child. Adult Medicaid Manual MA-2280. if the county will participate in the program. (2) If a CAP/DA beneficiary. program, contact the DMA CAP Unit at. b. The allotments are part of the CAP/DA allotment for each county. c. Requirement for county participation is the same as for CAP/DA in I.B.3.c. above. d. Lead agency selection is the same as CAP/DA in I.B.2.d. above. e. CAP/Choice uses a non-traditional case management service. CAP/Choice has four (4) additional services to the usual CAP/DA services. (1) Care Advisor: The care advisor replaces the case manager. Aquí nos gustaría mostrarte una descripción, pero el sitio web que estás mirando no lo permite. Nba 2k10 Manual Roster Update. included services and program locations of the NC Community Alternatives Program for. (CAP/DA) is North Carolina Medicaid's home and community based services. North Carolina Client Assistance Program (CAP) Resource Summary Page. North Carolina accessible vans sales. AMS offers quality wheelchair vans at. • Describe the actions DMA is taking to. CMS State Medicaid Manual. Scope of Authorized PCS. CAP/DA Private Duty Nursing. Adult Medicaid Manual MA-2280 COMMUNITY ALTERNATIVES PROGRAM (CAP) STATE OF NORTH CAROLINA PERFORMANCE AUDIT COMMUNITY ALTERNATIVES PROGRAM FOR DISABLED ADULTS (CAP/DA) Located within the Division of Medical Assistance. NCTracks Login | Help; The NCTracks Web Portal contains information that is private and confidential. NC MMIS retains the right to monitor, record. Manual Evinrude 70 Hp
Manual Evinrude 9.9Encontrá más de 199 Evinrude - Motores en Náutica en Envinrude, Mercury o Yamaha en Bs.As. G.B.A. Norte, Bs.As. G.B.A. Sur o Bs.As. Costa Atlántica. Oportunidad en Manual De Taller Y Despiece Evinrude Johnson! Más de 100 ofertas a excelentes precios en MercadoLibre Argentina: evinrude johnson 115 hp manual. Los motores fueraborda Evinrude E-TEC ofrecen rendimiento extraordinario. Hay modelos de 25 a 300 CV de potencia. ¡Solicite un presupuesto hoy mismo! Manual evinrude gratis, tutorial evinrude. 20 Ultimos. Top Valoracion. Top Semanal. Top Historico. Top Español. Búsqueda RESULTADOS: manual evinrude. Deciding on a new boat or engine? Evinrude E-TEC outboard motors deliver outstanding performance. Models range from 25 to 300 horsepower. Get a quote today! Advertencia, los manuales están es servidores públicos, si no funciona alguna descarga intente mas tarde. CLYMER EVINRUDE AND JOHNSON OUTBOARD MANUAL. CE6000 SERIES CUTTING PLOTTER SETUP MANUAL MANUAL NO.CE6000U-UM-8M2 Preface Thank you for choosing this product. Carefully keep this manual in a handy location for quick reference as necessity prior to use to ensure safe and correct use and also to thoroughly understand the functions and operate them effectively. Be sure to read the attached "TO ENSURE SAFE AND CORRECT USE" prior to use. Otherwise, it may cause an unexpected accident or fire. This User's Manual is copyrighted by Graphtec Corporation. Roles of each manual. [Update for the Graphtec CE6000 driver was completed] screen will appear. Click.SERVICE MANUAL MANUAL NO. FC4200-UM. *2 The figure varies with the type of Graphtec-designated medium. your sales representative or nearest Graphtec vendor to. Graphtec Service Manual.pdf. for our customers as a service only. Graphtec Plotter Controller. of lay planning in manual. (Graphtec CE5000-120AP. Graphtec ce5000 service manual, eureka forbes wet and dry vacuum cleaner manual, fairbanks morse magneto repair manual, dai fondamenti agli oggetti corso di. Graphtec ce5000 service manual, es1988s allegro audio driver, vizio xvthb100 bluetooth stereo headphones manual. GRAPHTEC SERVICE MANUAL. 2006 - ce5000-um-251-09-9370. ce5000 series. service manual. manual no. ce5000-um-251. cutting plotter. Date shared: Nov 12. Graphtec Ce5000 Service Manual allows you to pair your Graphtec Ce5000 Service Manual or iPhone over Bluetooth connection, and while it works well, there are some. CE6000 SERIES USER’S MANUAL MANUAL NO. CE5000-UM-152. Thank you for choosing a Graphtec CE5000 Series. please contact your sales representative or nearest Graphtec vendor. As soon as the PIEPS DSP picks up signals, the approximate distance and direction appear in the display. The number of burials within the range of the device. View and Download PIEPS DSP PRO manual manual online. Digital 3-antenna transceiver. DSP PRO Fitness Electronics pdf manual download. PIEPS DSP Manual PDF| 7 mb Beacon Fleet Compare PDF| 176 kb. Video. Extend warranty; SHARE. PIEPS GmbH Parkring 4 8403 Lebring, Austria Tel: +43 3182 52556. Pieps Dsp Manual AnswersPieps Freeride Avalanche Beacon Review - Duration: 2:11. by Steve Crowe 12,189 views. 2:11 How to do a seach with an Avalanche Beacon - Duration: 6:02. Pieps DSP PRO Pdf User Manuals. View online or download Pieps DSP PRO Manual Manual. Manual : Pieps : Backup : Download : Pieps : TX600. Download : Pieps : DSP (small buttons) Download : Pieps : DSP (large buttons) Download : Pieps : DSP Sport and. Pieps DSP avalanche beacon review for backcountry skiing and ski mountaineering. The Backcountry Skiing Blog. Home;. Manual. Shop for Pieps DSP avalanche beacon. MANUAL PIEPS DSP Pro | DSP SPort PREMIUM ALPINE PERfoRMANcE. PIEPS DSP Tour, PIEPS FREERIDE More information can be found on www.pieps.com. SEnD-MoDE. Oster Designer Instant Steamer 4711 Manual TransmissionYour ip blocked due to suspicious activity. Please enter CAPTCHA
Oster Steamer Manual 4711 Browse 1 Oster DESIGNER 4711 manuals for free PDF download. Oster #4711 Designer 6 quart Oster+Instant+Steamer+Instructions. The oster 4711 steamer is a self-contained. free download of oster 4711 user manual. troubleshooting help. Oster food steamer / rice cooker - model # 4711 in. Oster Designer 4711 Large Capacity Food Steamer Rice. More items related to oster food steamer 4711. OSTER 2 TIER FOOD STEAMER INSTANT STEAM,WORKS GREAT MANUAL. Free download of Oster 4711 User Manual. Troubleshooting help from experts and users. Ads related to Oster 4711 | | |. Kitchen Appliance Oster; Oster Electric Steamer; 4711; Support User Manuals. Filter; Top Products;. I do not have the manual to the bread maker oster model. Steam your way to healthy eating with the Oster® Manual Food Steamer. Instant steam feature; External. from Fantastic versatility I have had my Oster steamer. Oracle Primavera P6 Preface Primavera Project Planner (P3) provides an easy-to-use approach to project planning with an intuitive interface that makes project planning.Links to Primavera documentation libraries on OTN. Oracle. Country; Country; Communities;. Log In to My Oracle Support; Training and Certification; Become a Partner;. Primavera on the Oracle Technology Network (OTN) Use these tabs for quick access to resources you need to make the most of your Oracle Primavera solutions. Paul E Harris, author of over 50 project management training books and manuals, conducts project management training courses on Primavera software in Australia and. Manual, Primavera P6 Training Oracle Primavera P6 Training Manual for free from Primavera P6 Training Manual. Overview of Manually Upgrading a P6 Professional Database. Primavera P6 Enterprise Portfolio Management is a robust solution that helps manage and execute projects. See how it helps balance resource capacity. Title: Primavera P6 Training Manual Course 102 Keywords: Primavera P6 Training Manual Course 102 Created Date: 9/5/2014 2:05:36 PM. 7 Oracle Primavera provides comprehensive, multiproject planning and control software, built on Oracle and Microsoft® SQL Server databases for organization-wide project. Oracle Primavera P6 ® ™ Administrator’s Guide Version 7.0 Copyright © 1999, 2009, Oracle and/or its affiliates. All rights reserved. The Programs (which include both the software and documentation) contain proprietary information; they are provided under a license agreement containing restrictions on use and disclosure and are also protected by copyright, patent, and other intellectual and industrial property laws. Customers to operate and/or service Intermec manufactured equipment and is not to be released. 3400, 4420, and 4440 Cutter User’s Manual 4. Intermec 4420 4. Intermec EasyCoder 4440 Printer • In House Technicians. Experienced service consultants are always available to discuss data collection and printer issues. 44 Bar Code Label Printer User’s Manual *1233* ii Intermec Technologies Corporation 6001 36th Avenue West Everett, WA 98203-9280 U.S. service and.
Goodman Furnace Gmh95 Installation Manual Goodman GMH95 12. Ton Systems Quality you can Trust. goodman genesis air mitsubishi electric gree honeywell. GOODMAN GCH95 Installation Manual GOODMAN GCVC95 Installation Manual GOODMAN GDH8 Installation. Heat Pump & Gas Furnace Packaged Units; Packaged Unit Electric Heat.
Goodman Electric Furnace Manual -Janome memory craft 9000 manual Pdf Download, Living Goodman Air Conditioner 16 seer R410A Installation Instructions. Goodman Electric Furnace Manual -Janome memory craft 9000 manual Pdf Download. GOODMAN GAS FURNACE INSTALLATION MANUAL Gas/Electric Heat Pump. >>>CLICK HERE<<<. TECHNICAL MANU AL MANUAL Goodman Mfg Gas Fired Central Furnaces INSTALLATION & OPERATING INSTRUCTIONS GAS FIRED WARM AIR FURNACE AMV8. Goodman Mfg. Co. LP. Furnace User Manual. Pages: 0. TECHNICAL MANU AL MANUAL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2009 Goodman Manufacturing Company, L.P. RT6622011 September 2009 Copyright © 2005-2007 Goodman Manufacturing Company, L.P. PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. G BRAND: ® G: Goodman Brand D S 8 045 3 A X C MAJOR REVISION: A FURNACE TYPE S: Single Stage/ Multi-speed AIRFLOW CAPABILITY: 3: 1200 4: 1600 5: 2000 ADDITIONAL FEATURES: N: Natural Gas X: Low NOx MINOR REVISION: AFUE: 8: 80% AIRFLOW DIRECTION D: Dedicated Downflow H: High Airflow CABINET WIDTH: A: 14" B: 17 1/2" C: 21" NOMINAL INPUT: 045: 45,000 Btuh 070: 70,000 Btuh 090: 70,000 Btuh 115: 115,000 Btuh WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. WARNING Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING 2 PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* GHS80453AXC* GHS80704AXC* GHS81155CXC* * These models available in Low NOx WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN General Operation The G*S8 furnaces are equipped with an electronic ignition device used to light the burners and an induced draft blower to exhaust combustion products. An interlock switch prevents furnace operation if the inner blower door is not in place. Keep the blower access door in place except for inspection and maintenance. (See illustration on pages 5 and 6.) This furnace is also equipped with a self-diagnosing electronic control module. In the event a furnace component is not operating properly, the control module LED will flash on and off in a factory-programmed sequence, depending on the problem encountered. This light can be viewed through the observation window in the blower access door. Refer to the Troubleshooting Chart for further explanation of the LED codes and Abnormal Operation - Integrated Ignition Control section in the Service Instructions for an explanation of the possible problem. The rated heating capacity of the furnace should be greater than or equal to the total heat loss of the area to be heated. The total heat loss should be calculated by an approved method or in accordance with “ASHRAE Guide” or “Manual J-Load Calculations” published by the Air Conditioning Contractors of America. *Obtain from: American National Standards Institute 1430 Broadway New York, NY 10018 Location Considerations • • • The furnace should be as centralized as is practical with respect to the air distribution system. Do not install the furnace directly on carpeting, tile, or combustible material other than wood flooring. When installed in a residential garage, the furnace must be positioned so the burners and ignition source are located not less than 18 inches (457 mm) above the floor and protected from physical damage by vehicles. NFPA 54/ANSI Z223.1 - latest edition. In Canada, the furnaces must be vented in accordance with the National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system. Accessibility Clearances (Minimum) Unobstructed front clearance of 24" for servicing is recommended. MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS - INCHES Sides 1 Rear 0 Front* 3 Vent SW 6 B 1 Top 1 * 24" clearance for serviceability recommended. ** Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements. Note: In all cases accessibility clearance shall take precedence over clearances from the enclosure where accessibility clearances are greater. All dimensions are given in inches. High Altitude Derate When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both the gas fuel and combustion air as altitude increases. The kit will provide the proper design certified input rate within the specified altitude range. INPUT PER BURNER - 22,500 BTUH NATURAL GAS / 20,000 BTUH L.P. ELEVATION ABOVE SEA-LEVEL (FEET) 2000 US BURNER ORIFICE CANADA BURNER ORIFICE 44/55 44/55 3000 44/55 4000 45/56 47/57 4500 5000 45/56 6000 46/57 7000 47/58 8000 47/58 Notes: HA-02 HIGH ALTITUDE CONVERSION KIT REQUIRED Tabled data is based upon the furnace input being reduced for altitudes above sea level. U.S. 4% per 1,000 feet. Canada 10% derate for 2,000-4,000 feet. WARNING TO PREVENT POSSIBLE PERSONAL INJURY OR DEATH DUE TO ASPHYXIATION, THIS FURNACE MUST BE CATEGORY I VENTED. DO NOT VENT USING CATEGORY III VENTING. Category I Venting is venting at a non-positive pressure. A furnace vented as Category I is considered a fan-assisted appliance and the vent system does not have to be “gas tight.” NOTE: Single stage gas furnaces with induced draft blowers draw products of combustion through a heat exchanger allowing, in some instances, common venting with natural draft appliances (i.e. water heaters). All installations must be vented in accordance with National Fuel Gas Code High altitude kits are purchased according to the installation altitude and usage of either natural or propane gas. Refer to the chart above for a tabular listing of appropriate altitude ranges and corresponding manufacturer’s high altitude Natural Gas and Propane Gas kits. For a tabular listing of appropriate altitude ranges and corresponding manufacturer's High Altitude Pressure Switch kits, refer to either the Pressure Switch Trip Points & Usage Chart in this manual or the Accessory Charts in Service Instructions. 4 PRODUCT DIMENSIONS MODEL GHS80453AXC* GHS80704BXC* GHS80905CXC* A 14 1/2" 17 1/2" 21" B 12 1/2" 16" 19 1/2" MODEL GDS80453AXC* A B 14 1/2" GDS80703AXC* GDS80904BXC* GDS81155CXC* 17 1/2" 21" 12 1/2" 16" 19 1/2" 5 PRODUCT DESIGN Pressure Switch Trip Points And Usage Chart Trip Point ID Blower Pressure Switch -0.80 -0.70 -0.70 ID Blower Pressure Switch Part # 0130F00042 B1370158 B1370158 GHS8 Model GHS80453AXC* GHS80704BXC* GHS80905CXC* For installations in Canada, the GHS furances are certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) PRIMARY LIMIT Part Number Open Setting (°F) GHS80453AXC* GHS80704BXC* GHS80905CXC* 0130M00063 140 1 --1 20162903 120 --1 --- ROLLOUT LIMIT SWITCHES Part Number Open Setting (°F) GHS80453AXC* GHS80704BXC* GHS80905CXC* B1370145 300 2 2 2 AUXILIARY LIMIT SWITCHES Part Number Open Setting (°F) GHS80453AXC* GHS80704BXC* GHS80905CXC* 0130F00038 120 1 1 1 6 PRODUCT DESIGN Presssure Switches Model GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* Part No. B1370142 B137158 B1370142 B137158 Opens* -0.60 -0.70 -0.60 -0.70 GDS8 PRIMARY LIMIT Part Number Open Setting (°F) GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* 0130F00035 220 1 1 ----0130F00036 180 ----1 1 ROLLOUT LIMIT SWITCHES Part Number Open Setting (°F) GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* B1370145 300 2 2 2 2 AUXILIARY LIMIT SWITCHES Part Number Open Setting (°F) GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* 0130F00038 120 1 1 1 1 7 PRODUCT DESIGN Coil Matches: A large array of Amana® brand coils are available for use with the GHS8 furnaces, in horizontal applications and for the GDS8 for downflow applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existing Amana® brand coils as shown below. Coil Matches (for Goodman® units using R22 and R-410A): C PRODUCT TYPE: C: Indoor Coil A P F EXPANSION DEVICE: F: Flowrater 1824 A 6 A REVISION A: Revision CABINET FINISH: U: Unpainted P: Painted N: Unpainted Case APPLICATION A: Upflow/Downflow Coil H: Horizontal A Coil S: Horizontal Slab Coil REFRIGERANT CHARGE: 6: R-410A or R-22 2: R-22 4: R-410a NOMINAL WIDTH FOR GAS FURNACE A: Fits 14" Furnace Cabinet B: Fits 17 1/2" Furnace Cabinet C: Fits 21" Furnace Cabinet D: Fits 24 1/2" Furnace Cabinet N: Does Not Apply (Horizontal Slab Coils) NOMINAL CAPACITY RANGE @ 13 SEER 1824: 1 1/2 to 2 Tons 3030: 2 1/2 Tons 3636: 3 Tons 3642: 3 to 3 1/2 Tons 3743: 3 to 3 1/2 Tons 4860: 4 & 5 Tons 4961: 4 & 5 Tons • All CAPF coils in B, C, & D widths have insulated blank off plates for use with one size smaller furnaces. • All CAPF coils have a CAUF equivalent. • All CHPF coils in B, C & D heights have an insulated Z bracket for use with one size smaller furnace. • All proper coil combinations are subject to being AHRI rated with a matched outdoor unit. 8 PRODUCT DESIGN Thermostats: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will accommodate the following filter sizes depending on cabinet size: SIDE RETURN Approx. Cabinet Nominal Width Filter Size Flow Area (in.) (in.) (in2) All 16 x 25 x 1 400 BOTTOM RETURN Approx. Cabinet Nominal Width Filter Size Flow Area (in.) (in.) (in2) 17-1/2 14 x 25 x 1 350 21 16 x 25 x 1 400 24-1/2 20 x 25 x 1 500 Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return. UPFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 Input__Airflow UPFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 Input__Airflow 800 ------- 1000 564* ----- 1200 564* 752* 940* 1400 672 752* 940* 1600 768 768 940* 2000 800 ------- 1000 627* ----- 1200 627* 836* 940* 1400 672 836* 940* 1600 768 836* 940* 2000 --960 960 0704__XA 0905__XA 1155__XA ------- 0704__XA 0905__XA 1155__XA ------- 960 960 COUNTERFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 Input Airflow 0704__XA 0905__XA ----800 ----1000 641* --1200 641* 854* 1400 672 854* 1600 768 854* 2000 COUNTERFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 Input Airflow 0704__XA 0905__XA ----800 ----1000 320* --1200 320* 427* 1400 336 427* 1600 384 427* 2000 --480 --960 *Minimum filter area dictated by heating airflow requirement. *Minimum filter area dictated by heating airflow requirement. Disposable Minimum Filter Area (in2) [Based on a 300 ft/min filter face velocity] Permanent Minimum Filter Area (in2) [Based on 600 ft/min filter face velocity] 9 PRODUCT DESIGN Counterflow Filters This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace will accommodate the following filter sizes depending on cabinet size: Return Air Optional Access Door Counterflow Top Return Filter Area Qty Filter Size Dimension "A" (in) (in) (in2) 600 800 1000 2 2 2 15 X 20 X 1 20 X 20 X 1 25 X 20 X 1 13.0 11.3 18.8 17.7 24.3 23.4 Cabinet Width "A" Min 21 24 1/2 21 24 1/2 21 24 1/2 Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere in the duct system such as a central return. 10 FURNACE SPECIFICATIONS MODEL Btuh Input (US) High Fire Output (US) High Fire A.F.U.E. (2) (1) GDS8 45,000 36,000 80% .20 - .50 35-65 -0.60 10 X 6 1/3 70,000 56,000 80% .20 - .50 30-60 -0.70 GDS80453AXC* GDS80703AXC* GDS80904BXC* GDS81155CXC* 90,000 72,000 80% .20 - .50 35-65 -0.60 10 x 8 1/2 115,000 92,000 80% .20 - .50 40 - 70 -0.70 (1) Rated External Static (" w.c.) Temperature Rise (°F) Pressure Switch Trip Point (" w.c.) Blower Wheel (D" x W") Blower Horsepower Blower Speeds Max CFM @ 0.5 E.S.P. Power Supply Minimum Circuit Ampacity (MCA) Maximum Overcurrent Device Transformer (VA) Heat Anticipator (Amps) Primary Limit Setting (°F) Auxiliary Limit Setting (°F) Rollout Limit Setting (°F) Gas Supply Pressure (Natural/Propane) (" w.c.) Manifold Pressure (Natural/Propane) High Stage (" w.c.) Orifice Size (Natural/Propane) Number of Burners Vent Connector Diameter (inches) Shipping Weight (lbs.) (3) (5) (4) 10 x 6 1/3 10 x 10 3/4 Refer toairflow charts. 115-60-1 8.5 15 40 0.7 220 120 300 7 / 11 3.5 / 10 #43 / #55 2 4 120 115-60-1 8.5 15 40 0.7 220 120 300 7 / 11 3.5 / 10 #43 / #55 3 4 130 115-60-1 12.9 15 40 0.7 180 120 300 7 / 11 3.5 /10 #43 / #55 4 4 153 115-60-1 12.9 15 40 0.7 180 120 300 7 / 11 3.5 /10 #43 / #55 5 4 175 1 Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level. 2 DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes: • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½” FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. NOTES: * * * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. 11 FURNACE SPECIFICATIONS MODEL Input, Natural Gas (BTUH) Output, LP (BTUH) A.F.U.E. (2) (1) (1) GHS8 GHS80453AXC* 45,000 36,000 32,000 80.0% 0.20 - 0.50 15 - 45 -0.80 11” x 6” 1/2 GHS80704BXC* 70,000 56,000 48,000 80.0% 0.20 - 0.50 30 - 60 -0.70 11” x 8” 3/4 Refer to airflow charts. 115/60/1 115/60/1 11.8 15 40 -0.70 120 120 300 7 / 11 3.5 / 10 43 / 55 3 4 130 115/60/1 11.8 15 40 -0.70 140 120 300 7 / 11 3.5 / 10 43 / 55 4 4 153 GHS80905CXC* 90,000 72,000 64,000 80.0% 0.20 - 0.50 35 - 65 -0.70 11” x 10” 3/4 Output, Natural Gas (BTUH) Rated External Static (" w.c.) Temperature Rise (°F) Pressure Switch Trip Point (" w.c.) Blower Wheel (D" x W") Blower Horsepower Blower Speeds Max CFM @ 0.5 E.S.P. Power Supply (Volts/Hz/Ph) Minimum Circuit Ampacity (MCA) Maximum Overcurrent Device Transformer (VA) ID Blower Pressure Switch Trip Point (" w.c.) Primary Limit Setting (°F) Aux iliary Limit Setting (°F) Rollout Limit Setting (°F) Gas Supply Pres sure (Natural/Propane) (" w.c.) Manifold Pressure (Natural/Propane) (" w.c.) Orifice Size (Natural/Propane) Number of Burners Vent Connector Diameter (inches) Shipping Weight (lbs.) (3) (5) (4) 12.5 15 40 -0.80 140 120 300 7 / 11 3.5 / 10 43 / 55 2 4 120 1 Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level. 2 DOE AFUE based upon Isolated Combustion System (ICS) 3 Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 5 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes: • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½” FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. NOTES: * * * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude. The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. BLOWER PERFORMANCE SPECIFICATIONS BLOWER PERFORMANCE (CFM & Temperature Rise vs. External Static Pressure) Model GHS8 Tons AC EXTERNAL STATIC PRESSURE (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 ( Heating Speed As Shipped ) Motor Speed at 0.5" ESP CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM 1,739 1,422 1,207 991 2,097 1,596 1,380 1239 2,382 1,622 1,436 1,240 19 23 28 34 25 32 38 42 28 41 46 54 1,656 1,399 1,213 980 2,068 1,566 1,356 1191 2,315 1,603 1,391 1,214 20 24 27 34 25 33 38 44 29 42 48 55 1,601 1,378 1,197 958 2,012 1,534 1,328 1165 2,234 1,583 1,387 1,191 21 24 28 35 26 34 39 45 30 42 48 56 1,551 1,350 1,169 950 1,939 1,492 1,303 1133 2,158 1,556 1,356 1,157 21 25 29 35 27 35 40 46 31 43 49 58 1,513 1,305 1,158 937 1,869 1,445 1,274 1,104 2,078 1,516 1,325 1,120 22 26 29 36 28 36 41 47 32 44 50 60 1,460 1,413 1,353 1,275 1,220 1,178 1,131 1,103 1,068 924 910 874 High GHS8 0453AXC (Med)² Med Med-Lo Low High GHS8 0704BXC (Med)² Med Med-Lo Low High GHS8 0905CXC (Med)² Med Med-Lo Low NOTES: • • • • • • • 3.0 2.5 2.0 1.5 4.0 3.5 3.0 3.0 5.0 4.0 3.5 3.0 1,795 1,718 1,631 1,401 1,354 1288 1,239 1,192 1127 1,082 1,040 996 1,971 1,866 1,762 1,482 1,422 1,359 1,279 1,239 1,180 1,083 1,052 1,025 CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. The chart is for information only. For satisfactory operation, external static pressure must not exceed values shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The dashed (---) areas indicate a temperature rise not recommended for this model. The above chart is for U.S. furnaces installed at 0' - 2,000'. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 13 BLOWER PERFORMANCE SPECIFICATIONS BLOWER PERFORMANCE (CFM & Temperature Rise vs. External Static Pressure) Model GDS8 Tons AC EXTERNAL STATIC PRESSURE (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 ( Heating Speed As Shipped ) Motor Speed at 0.5" ESP CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM 1,353 1,183 980 778 1,290 1,139 962 787 2,128 1,840 1,602 1,277 2,405 1,880 1659 1,472 25 28 34 43 40 46 54 66 31 36 42 52 35 45 51 58 1,290 1,113 946 762 1,236 1,090 927 776 2,063 1,788 1,558 1,252 2,361 1,838 1,630 1,454 26 30 35 44 42 48 56 67 32 37 43 53 36 46 52 59 1,246 1,098 920 738 1,194 1,035 925 763 2,001 1,745 1,543 1,244 2,250 1,794 1,587 1,404 27 30 36 45 43 50 56 68 33 38 43 54 38 47 54 61 1,199 1,052 900 746 1,166 1,063 941 744 1,927 1,689 1,493 1,229 2,161 1,734 1,537 1,366 28 32 37 45 44 49 55 70 35 39 45 54 39 49 55 62 1,149 1,039 896 738 1,176 1,063 909 723 1,824 1,625 1,455 1,214 2,037 1,677 1,492 1,326 29 32 37 45 44 49 57 72 37 41 46 55 42 51 57 64 1,116 1,116 1,099 1,006 1,012 969 885 717 855 696 804 678 HIGH GDS8 0453AXC (Med)² MED MED-LO LOW HIGH GDS8 0703AXC (Med)² MED MED-LO LOW HIGH GDS8 0904BXC (Med)² MED MED-LO LOW HIGH GDS8 1155CXC (Med)² MED MED-LO LOW NOTES: • • • • • • • 3.0 2.5 2.0 1.5 3.0 2.5 2.0 1.5 4.0 3.5 3.0 2.5 5.0 4.0 3.5 3.0 1,166 1,108 1,029 1020 877 690 962 834 641 895 779 581 1,726 1,628 1,529 1,550 1,470 1,364 1,402 1,328 1,239 1,179 1141 1079 1,937 1,808 1,689 1,568 1,510 1,401 1,445 1,368 1,287 1300 1228 1139 CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. The chart is for information only. For satisfactory operation, external static pressure must not exceed values shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The dashed (---) areas indicate a temperature rise not recommended for this model. The above chart is for U.S. furnaces installed at 0' - 2,000'. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 14 BTU OUTPUT vs TEMPERATURE RISE CHART 100 600 CFM 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM 90 80 70 60 TEMPERATURE RISE 50 BLOWER PERFORMANCE SPECIFICATIONS 40 30 FORMULAS BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 20 10 50 60 70 80 90 100 OUTPUT BTU/HR x 1000 110 120 130 140 150 30 40 15 WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. G*S8 BOX Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 16 RME OctaMic User's Manual can be found in Pre Amplifier documentation. The Manual is provided by Rme, a provider of Professional Audio and can be downloaded by. Your ip blocked due to suspicious activity. Please enter CAPTCHA Rme audio OctaMic Pdf User Manuals. View online or download Rme audio OctaMic User Manual. RME Audio OctaMic owners manual was published in PDF format. There is only one kind of Manual. The PDF manual can be easily download at no costs. RME Audio provides. View and Download RME Audio OctaMic II user manual online. Professional Mic / Line Preamp and AD-Converter 8-Channel Microphone / Line Preamp with Line Outputs 8. Manual clear in all languages. Not even need to use it. I bought this RME OctaMic II first as an extension to my future soundcard RME Fireface UC. OctaMic / OctaMic D Portable Professional Mic Preamp 8 -channel Microphone / Line Preamp with Line Outputs. OctaMic_e.PDF Created Date: Dienstag, 30. RME OctaMic II User's Manual can be found in Pre Amplifier documentation. The Manual is provided by Rme, a provider of Professional Audio and can be downloaded. OctaMic II Professional Mic. • OctaMic II • Power cord • Manual • 1 optical cable (TOSLINK). The OctaMic will now generate an output signal in the Quad. Rme Octamic Manual |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |